48T
$299.00
96T
$399.00
Species:
Mouse
Alternative Name:
PLA2IID, SPLASH, sPLA2-IID, sPLA2S
Uniport ID:
Q9WVF6
Assay Type:
Sandwich
unit:
pg/mL
Standard:
2000pg/mL
Sensitivity:
18.75 pg/mL
Detection Range:
31.25-2000pg/mL
Assay Time:
3.5H
Sample Type:
Serum, Plasma, Tissue homogenate and Other biological samples;Sample Volume=100μL
Research:
Metabolic pathway;Tumor immunity;Neuro science;Hormone metabolism;
Test Principle:
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Mouse PLA2G2D. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse PLA2G2D and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse PLA2G2D, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Mouse PLA2G2D.You can calculate the concentration of Mouse PLA2G2D in the samples by comparing the OD of the samples to the standard curve.
| pg/mL | OD | Corrected |
|---|---|---|
| 2000 | 2.313 | 2.284 |
| 1000 | 1.519 | 1.49 |
| 500 | 0.888 | 0.859 |
| 250 | 0.405 | 0.376 |
| 125 | 0.226 | 0.197 |
| 62.5 | 0.126 | 0.097 |
| 31.25 | 0.079 | 0.05 |
| 0 | 0.029 | 0 |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.
| Intra-assay Precision | Inter-assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 20 | 20 | 20 | 20 | 20 | 20 |
| Mean(ng/mL) | 51.22 | 360.53 | 714.43 | 65.24 | 517.38 | 902.62 |
| Standard deviation | 2.07 | 14.46 | 39.51 | 2.1 | 21.4 | 26.21 |
| C V (%) | 6.77 | 4.89 | 4.56 | 6.13 | 6.31 | 6.95 |
| Sample Type | Range(%) | Average Recovery(%) |
|---|---|---|
| Serum (n=8) | 85-97 | 91 |
| EDTA plasma (n=8) | 87-99 | 93 |
| Cell culture media (n=8) | 80-93 | 85 |
| Serum (n=5) | EDTA plasma (n=5) | Cell culture media (n=5) | ||
|---|---|---|---|---|
| 1:2 | Range (%) | 87-96 | 87-96 | 88-102 |
| Average (%) | 88 | 90 | 88 | |
| 1:4 | Range (%) | 85-98 | 92-105 | 87-102 |
| Average (%) | 95 | 97 | 90 | |
| 1:8 | Range (%) | 89-102 | 89-102 | 85-96 |
| Average (%) | 101 | 99 | 95 | |
| 1:16 | Range (%) | 85-98 | 92-101 | 87-101 |
| Average (%) | 98 | 99 | 92 |